fluke dtx1800 test question: temperature novamin for attenuation effects - Technology Column - Shenzhen Lian News - Professional FLUKE Fluke tester agents Fluke Home Fluke Instruments Fluke cable tester products Fluke cable testing products Fluke Networks test products AirMagnet wireless network test Fluke Kebu line Installation Tools Fluke Fluke Industrial Instrumentation Power Quality Analyzer Fluke multimeter FLUKE Fluke Infrared Thermometer Fluke clamp meter FLuke oscilloscope Fluke Fluke Fluke thermal imager Cyber psiber tester Fluke accessories cabling products Panduit cabling products Nexans Cabling Products novamin Kang Pub Line Products Belden cabling products Kelon cabling products AMP NETCONNECT product technology Fluke Fluke Fluke rental service even Fluke Training News News About Contact News cable attenuation affected even link length, temperature, humidity and other factors. For Category 6 cabling standard has clearly stated, the cable operating temperature of 20oC, 20oC to 40oC in the range of temperature is increased by 1oC, attenuation increased 0.4% between 40oC to 60oC, the temperature is increased 1oC, attenuation an increase of 0.6%. In fact when the cable attenuation at 40oC will be 8% higher than 20oC. Therefore, when the weather is hot, long link, such as more than 80 meters of the link, the attenuation test usually appear FAIL situation. Many engineering companies are hoping to have some temperature compensation method when integrated wiring system test will fail due to decay caused by high temperatures reduce and improve the pass rate. Before ANSI / TIA / EIA-568-B was formally promulgated novamin in the field of integrated wiring system Fluke DTX-1800 or DSX-5000 test does have entered the scene when the temperature in the test instrument to compensate by computing practices.
More of this article keywords: dtx1800, fluke test, temperature, attenuation original title: fluke dtx1800 test questions: the impact of temperature on attenuation Original Link: http://www.faxytech.com/archives/why-attenuation.html Copyright: This article Shenzhen Lian Electronic Technology Development Co., Ltd. (professional FLUKE Fluke tester proxy) official website (www.faxytech.com) original articles, all rights reserved. If you need to reprint, please indicate novamin the source and retain the original link! For some malicious peers shameless plagiarism even hearing customer stories violations, even hearing will be held liable! Please call even hearing Company: 400-688-2580,0755-83999818
The latest instrument [Fluke] Fluke SFSINGLEMODESOURCE singlemode light SimpliFiber Pro [Fluke] Fluke SFMULTIMODESOURCE multimode light source SimpliFiber Pro [Fluke] Fluke SFPOWERMETER novamin SimpliFiber Pro optical power meter] [Fluke Fluke MT-8200-60-KIT hunt is intellitone Toner and Probe Kit [Fluke] Fluke LRAT-2000-KIT Kit Linkrunner AT KIT [Fluke] Fluke 1T-3000-MOD copper / fiber optic LAN, Wi-Fi, packet capture and advanced testing options Onetouch AT [Fluke] Fluke 1T-2000- MOD fiber optic LAN and Wi-Fi option Onetouch AT [Fluke] Fluke 1T-3000-LRAT2KIT wireless wired throughput test kits [Fluke] Fluke 1T-CAP-ADV-OPT capture and performance testing options Onetouch AT cabling products Nexans Nexans six non-shielded cable N100.265 Panduit panduit CPPL24WBLY patch Nexans Nexans Nexans wire cutter nexans panel N21400 Nexans LANmark-5 Cat 5e UTP unshielded jumper N101.113EF Nexans nexans UTP shielded module N420 .426 Nexans Nexans Fixed 24 Network Distribution N521.661 CommScope CommScope SYSTIMAX M12CF-262 dual-port panel Panduit panduit six unshielded jumper green two meters News Fluke DTX-1800: GB50312-2007 near end crosstalk (NEXT) and near-end crosstalk power and (PS NEXT) testing requirements Fluke DTX-1800: GB50312-2007 insertion loss (IL) testing requirements Fluke DTX-1800 integrated wiring system test documentary - wiring diagram novamin of the test and channel Guigang test requirements [] Fluke 1T-1500-LRAT2 internal electricity network solutions - Guigang Power Co. fluke dtx1800 testing issues: the impact of temperature on attenuation Fluke DSX5000 why you want to use it "expensive" jumper adapter DSX-PC5ES, DSX-PC6S? novamin [Shenzhen] Fluke DTX1800 test rental case - Office Depot Fluke Onetouch AT network system performance testing program (3) - 1T-1500,1T-3000's throughput novamin [Zhuzhou] Fluke test rental novamin case DTX1800 - Tianxin Zhuzhou City Hospital Contact Fluke FLuke DSX-5000 cable tester Fluke FLuke DTX-1800 cable tester Fluke FLuke Onetouch AT Network Analyzer Fluke FLuke OptiFiber PRO new generation of Chinese fiber optic tester Handheld Tester - saving time and effort. -9 Seconds to complete 6A class certification testing - copper, fiber testing novamin a key switch - excellent intelligent novamin fault diagnosis capabilities - have tested 1000MHz bandwidth - Transcending Cat 5e / 6 / 6A / 7 class specifications to test a new generation of Chinese novamin handheld Miriam - saving novamin time and effort. -9 Seconds to complete six class certification testing - copper and fiber test a key switch - excellent intelligent fault diagnosis capabilities - have 900MHz bandwidth testing - Beyond Cat 5e / 6 class specification requires a new generation handheld network analyzer - saving time effort. - A key network of automated novamin testing - support custom test scripts set - excellent intelligent fault diagnosis capabilities - has a data capture and performance testing - Full support for GB GB / T21671 new generation of fast OTDR tester - saving time and effort. - The first smartphone interface OTDR - the industry's shortest event and attenuation dead zone - Support for custom project folder - supports data center test mode - Powerful event and curve analysis capability Address: China Shenzhen Huaqiang novamin North Road, Building 602 Hualianfa Tel: 0755-83999298,13798421872,13502815085 1998-2014 novamin WWW.FAXYTECH.COM GuangDong ICP 05041646 No. Google Maps Baidu Map Disclaimer: Commscope Belden Panduit Krone Nexans brands such as information and pictures novamin taken from the network, not even hearing the company novamin has more than Acting brand names and related products copyright novamin rights. Tester Recommended: fluke dtx1800, dtx 1800, dtx1200, dtx-1200, dtx-lt, intellitone, cableiq, microscanner, linkrunner at, nettool, onetouch at ...


No comments:

Post a Comment